Casio QV-2900UX Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Aparaty z pseudo lustrem Casio QV-2900UX. Casio QV-2900UX Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - QV-2900UX

RQV-2900UX(KX-787)JUL. 2001(without price)INDEX

Strona 2 - CONTENTS

— 8 —2-2. Upgrading using CF card1.Copy the latest upgraded program (_romXXXX.bin) and graphic menu (_gmenuXXXX.bin) on CF card’sroot directory and s

Strona 3 - SPECIFICATIONS

— 9 —3. Test modeNote: Do not perform the menu item unless explained here.(It may damage the internal data and camera becomes unusable.)3-1. BootingTo

Strona 4

— 10 —3 MENU24 MENU3

Strona 5 - BLOCK DIAGRAM

— 11 —4. Adjustment4-1. Flash adjustment1. GeneralWhen you exchange a flash unit or lens unit please perform this adjustment.2. Necessary equipment(1)

Strona 6 - ■ Preparation

— 12 —QV-2900UX70 cmTV monitor(with a video input terminal)Video cableBack ground paper4-2. Flash operation and recharge operation1. GeneralWhen you e

Strona 7 - 1. PROGRAM LOADING

— 13 —4-3. Current consumption1. GeneralWhen consumption of a battery is early, check.2. Conditions•Set QV-2900UX to “PLAY” mode.3. Preparation(1) Vol

Strona 8

— 14 —4-4. VCOM DC adjustment1. GeneralPerform these adjustments when you replace LCD module or D-PCB.2. Preparation(1) AC adaptor or stabilizer.(2) P

Strona 9 - 2. Program version upgrading

— 15 —Note: Easy adjustment(1) Boot MENU 1 on the test mode.1. Turn the camera on while pushing SHIFT and MENU keys.2. Push SHIFT keys twice then MENU

Strona 10

— 16 —4-5. Operation check1. GeneralAfter repairs, please check if needed.2. Preparation(1) Batteries.(2) AC adaptor.(3) PC (IBM compatible)/OS:Window

Strona 11 - 3. Test mode

— 17 —5. D-PCB Assy5-1. VCO free run frequency adjustmentRoom temperature should be 20 ± 10 °C1. Preparation•AC adaptor or voltage regulator•Frequency

Strona 12

CONTENTSSPECIFICATIONS ...

Strona 13 - 4. Adjustment

— 18 —D-PCBVR(CP320)VB(CP324)VG(CP322)Figure 1Digital oscilloscopeKiller terminal(CP308)QV-2900VCC522KΩPowerSupply5-3. RGB AMP and Sub-Brightness volt

Strona 14 - Back ground paper

— 19 —5-4. Contrast and Brightness voltage setting adjustment1. Preparation•AC adaptor or voltage regulator•Digital oscilloscope2. Adjustment procedur

Strona 15

— 20 —5-5. TINT setting adjustment1. Preparation•AC adaptor or voltage regulator•Digital oscilloscope2. Adjustment procedure(1) Start up Test mode Men

Strona 16

— 21 —6. PW-PCB Assy6-1. VCC3, VCC3-MD, VCC5, VCC7.5, EVCC3 Voltage check1. Preparation•AC adaptor or voltage regulator•Multimeter2. Adjustment proced

Strona 17 - Note: Easy adjustment

— 22 —DISASSEMBLYToolSoldering iron / solder / desoldering wireprecision screwdrivers / TweezersDischarge tool (Resistor 1.5 kΩ 5 W)Main block2. Remo

Strona 18

— 23 —7. Pull to the right with pushing the arrowed area.8. Remove the front case block.9. Rotate the lens and remove the screw on theside.10. Rotate

Strona 19 - 5. D-PCB Assy

— 24 —15. Remove the connector (CN900).16. Remove the connector (CN101).17. Lift up the bending of solderless terminal.18. Remove the silver screw.19.

Strona 20

— 25 —2. The screw (1.7 × 9 black)3. Remove the JK-PCB.4. Remove the connector (CN800).5. Remove the battery cover.6. Remove the screw at the bottom

Strona 21

— 26 —10. Remove the battery holder.11. Remove the screw.12. Remove the KA-PCB.13. Remove the screw.14. Remove the screw.9. Remove the connector (CN10

Strona 22 - 5-5. TINT setting adjustment

— 27 —1. Remove the screw.2. Remove the D-PCB.Upper case block3. Remove the connector (CN540).4. Remove the connector (CN340).5. Remove the screw.6. R

Strona 23 - 6. PW-PCB Assy

— 1 —SPECIFICATIONSFile Format Still images (including panoramas): JPEG (Exif. Ver. 2.1) / TIFF, DCF standard (Design rule forCamera File system), DPO

Strona 24 - Main block

— 28 —11. Remove the screw.12. Remove the KB-PCB.9. Remove the LCD.10. Remove the screw.

Strona 25

— 29 —1. Remove the screw.2. Remove the screw.3. Remove the case.4. Peel off the insulation sheet.5. Discharge flash capacitor.(locates between CP400

Strona 26

— 30 —7. Remove the screw. (1.7×12 silver)✽ tips for the assemblyTighten the screw as hard as there is a space.8. Remove the screw.9. Remove the conne

Strona 27 - Lower case block

— 31 —14. Remove the connector (CN250).15 Remove the connector (CN290).16. Remove the screw.17. Remove the C-PCB.18. Unsolder two lead wires.19. Remov

Strona 28

— 32 —22. Remove the MD-PCB.23. Rotate L-case unit and remove the screw .24. Remove the screw.25. Remove the L-case unit.

Strona 29 - Upper case block

— 33 —EXPLODED VIEW8493215136144118314739262543 54S521327S453S2335124S5S819524448S742S834658S923S42212S655507S9575S6S440S65617920S3101646214537S6S7S6S

Strona 30 - 10. Remove the screw

MAIN BODY COMPONENTNItemCode No.Parts NameSpecificationApplicableQPrice CodeR11003 4054BACK LIGHT ASSYK342253*1 TK(K715)Common1CRA21002 8729CABLE/BACK

Strona 31 - Lens block

NItemCode No.Parts NameSpecificationApplicableQPrice CodeR511000 1733CUSHIONK441962-1Common1AAX521003 4797TAPE/INSULATIONRJK501511-001V01Common1AAX531

Strona 32

PCBNItemCode No.Parts NameSpecificationApplicableQPrice CodeRBL-PCBCN9003502 2230CONNECTORSM03B-SRSS-TBCommon1ACXQ9022259 2744TRANSISTOR/DIGITALDTA143

Strona 33

NItemCode No.Parts NameSpecificationApplicableQPrice CodeRKB-PCBSW8953412 1995SWITCH/TACTSKQRAA-TCommon1ABCSW8963412 1995SWITCH/TACTSKQRAA-TCommon1ABC

Strona 34 - 25. Remove the L-case unit

— 2 —Viewfinder LCD Monitor or optical viewfinderClock Built-in quartz digital timepiece for time and date recording and storage with image data; auto

Strona 35

— 38 —PRINTED CIRCUIT BOARDSDIGITAL-PCB (PCB 715-D)

Strona 36 - PARTS PRICE LIST

— 39 —POWER-PCB (PCB 715-PW)BACK LIGHT-PCB (PCB 715-BL)

Strona 37

— 40 —JACK-PCB (PCB 715-JK)KA-PCB (PCB 715-KA)

Strona 38

— 41 —KB-PCB (PCB 715-KB)C-PCB (PCB 717-C)

Strona 39

— 42 —MD-PCB (PCB 717-MD)

Strona 40 - DIGITAL-PCB (PCB 715-D)

— 43 —CCD-PCB (PCB 717-CCD)ST-PCB (PCB 717-ST)

Strona 41 - BACK LIGHT-PCB (PCB 715-BL)

— 44 —SCHEMATIC DIAGRAMSDIGITAL-PCB (PCB-715A-D)

Strona 42 - KA-PCB (PCB 715-KA)

— 45 —POWER-PCB (PCB-715A-PW)

Strona 43 - C-PCB (PCB 717-C)

— 46 —BACK LIGHT-PCB (PCB-715A-BL)

Strona 44 - MD-PCB (PCB 717-MD)

— 47 —JACK-PCB (PCB-715A-JK)

Strona 45 - ST-PCB (PCB 717-ST)

— 3 —BLOCK DIAGRAMC-PCBMD-PCBC-FPCICX284AQCCD(2Mpix)15.0V-7.5V3.3V22pin 80pin22pin22pin36.0MHz3.3V5.0V15.0V-7.5VCDSSENCDSSCKCDSSDATATGSENTGSCKTGSDATAT

Strona 46 - DIGITAL-PCB (PCB-715A-D)

— 48 —KEY-PCB (PCB-715A-KA)

Strona 47 - POWER-PCB (PCB-715A-PW)

— 49 —KEY-PCB (PCB-715A-KB)

Strona 49 - JACK-PCB (PCB-715A-JK)

— 51 —MD-PCB (PCB-717MD)

Strona 50 - KEY-PCB (PCB-715A-KA)

— 52 —CCD-PCB (PCB-717CCD)

Strona 51 - KEY-PCB (PCB-715A-KB)

— 53 —ST-PCB (PCB-717A-ST)

Strona 52 - C-PCB (PCB-717C)

CASIO TECHNO CO.,LTD.Overseas Service DivisionNishi-Shinjuku Kimuraya Bldg. 1F5-25, Nishi-Shinjuku 7-ChomeShinjuku-ku, Tokyo 160-0023, Japan

Strona 53 - MD-PCB (PCB-717MD)

— 4 —ADJUSTMENT Preparation1. PC (IBM Compatible)/OS:Windows 95/982. Link cable.3. Adjustment program1) adj715.exe (Color adjustment data transfer pr

Strona 54 - CCD-PCB (PCB-717CCD)

— 5 —1. PROGRAM LOADING1-1. Important noticeFlash ROM on the D-PCB contains camera’s operating program and graphic menu. The D-PCB is used inthe model

Strona 55 - ST-PCB (PCB-717A-ST)

— 6 —7. Connect an AC adaptor and turn the camera on within 5 seconds. Camera may be turned on automaticallywhen an AC adaptor is connected. If not, u

Strona 56 - CASIO TECHNO CO.,LTD

— 7 —2. Program version upgradingPlease check the version and update it if the version is not updated.Note: Be sure to use AC adaptor.2-1. How to conf

Komentarze do niniejszej Instrukcji

Brak uwag