Casio CTK-620L Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 33
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
— 12 —
3) Equipment connection/Procedure
Vop voltage setting
Output
Set Voltmeter
TP3
37.6°
LCD
Eye
Watching the LCD at a 37.6° angle to the horizontal, adjust Vop
voltage so that unenergized segments are seen dimly.
ADJUSTMENT
DISPLAY PCB
1) Items to be adjusted:
metItnemurtsnIgnirusaeM
gnittesegatlovpoVretemtloV
2) Adjustment and Test Point Locations
(TOP VIEW)
VR401
TP3
Input
Connection
Input
Point
Input
Signal
Adjust
Output
Connection
Output
Point
Adjust for
VR401 Voltmeter TP3 Adjust for 4.2 ~ 4.3 V reading
on voltmeter under the tem-
perature 20 ~ 25 °C.
Make fine adjustment accord-
ing to the next instruction.
Przeglądanie stron 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 32 33

Komentarze do niniejszej Instrukcji

Ender Carroz 14 Sep 2024 | 23:31:30

Muy buena información.

Ender Carroz 14 Sep 2024 | 23:34:00

Muy buena información.