6. Cable Specifications
6.1 For Chain Connection and Short Length
Length; 1 meter or less
Fig. 6.1
Table 6.1 Specifications of the cable
Cable
Conductor 20/0.1A
Insulator Semi-hard material P.V.C.
Core wire
Finish of external shape 20/0.1A
Insulator P.V.C. Sheath
Finish of external shape φ4.3±0.1mm
Conductance resistance 0.12/m or less Characteristics
Insulation resistance 50M or more
Pin layout diagram of cable for chain connection and short distance (pin-to-pin straight connection)
Wiring
Fig. 6.2
Pin no. Signal
1 ORS+
2 ORS-
3 OSD+
4 OSD-
5 IRD+
6 IRD
Pin no. Signal
1 IRS+
2 IRS-
3 ISD+
4 ISD-
5 ORD+
6 ORD-
Max. 1m
1 2 3 4 5 6 1 2 3 4 5 6
Modular plug compatible
with