Casio E-CON Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Casio E-CON. E-con for Web ~2-14/7.6 - Support Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 25
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Chapter
All of the explanations provided here assume that you are already familiar
with the operating precautions, terminology, and operational procedures of
the calculator and the EA-100.
E-CON Ver. 1.20
Software for the ALGEBRA FX 2.0 Series
1. E-CON Overview
2. EA-100 Setup
3. Setup Memory
4. Program Converter
5. Starting a Sampling Operation
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - E-CON Ver. 1.20

ChapterAll of the explanations provided here assume that you are already familiarwith the operating precautions, terminology, and operational procedur

Strona 2 - 1. E-CON Overview

(4) Measurement Time Recording Method (Rec Time)• 1(None) ... No time recorded.• 2(Abs) ... Absolute time in seconds from start of sampling•

Strona 3 - 2. EA-100 Setup

2. Use the function key operations described below to change Trigger Setup settings.•To change the setting of an item, first use the f and c cursor ke

Strona 4 - Before getting started

OptionUse the Option Setup screen to make View Window settings, to specify the channel for real-time sampling, and to make filter settings.• To change

Strona 5

(3) Real-time Sampling Channel (Use CH)• 1(CH1) ... Channel 1• 2(CH2) ... Channel 2• 3(CH3) ... Channel 3• 4(SONIC) ... Sonic channel•

Strona 6

• To configure a custom probe starting from the Advanced Setup menu1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display theAdvance

Strona 7

• To configure a custom probe starting from the Channel parameter setting screen1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to displ

Strona 8

u To use the MULTIMETER ModeYou can use the Channel parameter settings of Advanced Setup to configure a channel sothat EA-100 MULTIMETER Mode sampling

Strona 9

3-1Setup Memory3. Setup MemoryYou can use setup memory to save EA-100 setups you create using Setup Wizard orAdvanced Setup in calculator memory for l

Strona 10 - EA-100 Setup

2. Press 2(SAVE).• This displays the screen for inputting the setup name.3-2Setup Memory3. Press w and then input a memory number (1 to 99).• This sav

Strona 11

u To recall a setup and use it for samplingBe sure to perform the following steps before starting sampling with the EA-100.1. Connect the calculator t

Strona 12

1-1E-CON Overview1. E-CON Overview• From the Main Menu, select E-CON to enter the E-CON Mode.• The E-CON provides the functions listed below for simpl

Strona 13

u To delete setup data1. On the E-CON main menu, press 2(MEM) to display the setup memory list.2. Use the f and c cursor keys to highlight the name of

Strona 14

4. Program ConverterProgram Converter converts an EA-100 setup you created using Setup Wizard or AdvancedSetup to a program that can run on the calcul

Strona 15

3. Press w.• This starts conversion of the setup data to a program.• The message “Complete!” appears when conversion is complete.u To convert setup da

Strona 16

5. Starting a Sampling OperationThe section describes how to use a setup created using the E-CON Mode to start an EA-100sampling operation.k Before ge

Strona 17 - 3. Setup Memory

u To start sampling1. Start the sampling operation by performing one of the function key operations describedbelow.• If the final Setup Wizard screen

Strona 18 - Setup Memory

5-3Starting a Sampling Operation Real-Time Normal Sampling Normal Sampling Trigger Start [TRIGGER] Key PhotogateSampling TypeSamplingPress [EXE] to s

Strona 19

2. EA-100 SetupYou can use the E-CON Mode to set up the EA-100 for sampling and then start samplingimmediately or save the setup in calculator memory.

Strona 20

u To create an EA-100 setup using Setup WizardBefore getting started...• Before starting the procedure below, make sure you first decide if you want t

Strona 21 - 4. Program Converter

6. After you complete step 5, a screen for setting the number of samples appears on thedisplay.• Use the number keys to input the number of samples, a

Strona 22 - Program Converter

k Creating an EA-100 Setup Using Advanced SetupAdvanced Setup provides you with total control over a number of parameters that you canadjust to create

Strona 23 - Starting a Sampling Operation

•You can return the settings on the above setup screens (b through e) using theprocedure described under “To return setup parameters to their initial

Strona 24

• To change Channel parameter settings1. While the Advanced Setup menu is on the display, press b(Channel).• This displays the Channel parameter setti

Strona 25 - Starts Sampling

SampleSelecting this parameter displays a screen for making real-time settings, and for specifyingthe sampling interval, number of samples, measuremen

Komentarze do niniejszej Instrukcji

Brak uwag