Casio E-Con EA-200 Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Oprogramowanie Casio E-Con EA-200. Casio E-Con EA-200 User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User’s Guide

User’s GuideEA-200http://world.casio.com/edu_e/E

Strona 2 - FCC WARNING

20020601English1-4(2) Send Command 1 to configure channel settings.• Voltage Probe (that is connected to CH1.){1, 1, 2} → List 1_____ The first 1 is t

Strona 3 - Contents

20020601English1-5Using the Built-in SpeakerTo output sound recorded by the built-in microphone(1) Send Command 0 to initialize the EA-200 setup.{0}

Strona 4 - Handling Precautions

20020601English1-64. Press the EA-200 [START/STOP] key to start sampling.• The Sampling lamp flashes as sampling is performed.5. Press the [START/STOP

Strona 5 - About the EA-200

 ExamplesUniformly Accelerated MotionPeriod of Pendular MovementConservation of MomentumCharles’ LawPolarization of LightNatural Frequency and SoundC

Strona 6 - AC Adaptor

20020601EnglishActivity: SetupActivity: Setup2-1-1쐽 EquipmentCart Ramp Stand ProtractorDistance Measurement Setup (EA-200, graphic scientific calculat

Strona 7 - Chapter 1

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-1-2555555555555555555555555555555555555555555

Strona 8 - Supported Probes

20020601English쐽 EquipmentString with little elasticity Weight Stand Height adjustment blocks (2)Optical Measurement Setup (EA-200, graphic scientific

Strona 9 - Using Commands

20020601English쐽 Calculator Operationu Perform the following operation to prepare for light measurement using the optical probe.Using E-CONUsing a Cal

Strona 10 - Using the Built-in Microphone

20020601English쐽 EquipmentTwo carts of identical mass String Pulley with a bracket to secure itVelcro쑓 500g weight CushionDistance Measurement Setup (

Strona 11 - Auto Setup

20020601English쐽 Calculator Operationu Find the applicable program in the Program Library (P.2-16-1), input it into your calculator,and then run it.u

Strona 12 - Group Link Function

In no event shall CASIO Computer Co., Ltd. be liable to anyone for special, collateral,incidental, or consequential damages in connection with or aris

Strona 13 - Chapter 2

20020601EnglishActivity: SetupActivity: Setup2-4-1쐽 EquipmentSyringe (with scale markings) Plastic Container Rubber TubeRubber Gasket Clip Mixing Stic

Strona 14 - Uniformly Accelerated Motion

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-4-2555555555555555555555555555555555555555555

Strona 15 - 55555555555555555555555

20020601EnglishActivity: SetupActivity: Setup2-5-1쐽 EquipmentPolarizers (2) Thick Paper Wood PenlightGlass Screen ProtractorOptical Measurement Setup

Strona 16 - Period of Pendular Movement

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-5-2555555555555555555555555555555555555555555

Strona 17

20020601EnglishActivity: SetupActivity: Setup2-6-1쐽 EquipmentBox String Bolts (2) Triangular Wood Blocks (2)Audio Measurement Setup (EA-200, graphic s

Strona 18 - Conservation of Momentum

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-6-2쐽 Measuring the Sound Frequencyu Position

Strona 19

20020601EnglishActivity: SetupActivity: Setup2-7-1쐽 EquipmentGlass Resonance Tube (Uniform Inside Diameter, With Scale Markings)Rubber Tube Reservoir

Strona 20 - Charles’ Law

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-7-2쐽 Measuring the Resonance Pointsu Record t

Strona 21

20020601EnglishActivity: SetupActivity: Setup2-8-1쐽 EquipmentPiano (Sound Source) Computer (MIDI Sound Source)Audio Measurement Setup (EA-200, graphic

Strona 22 - Polarization of Light

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-8-2555555555555555555555555555555555555555555

Strona 23

20020601English0-1Contents–– English ––Handling Precautions ... 0-2Unpacking

Strona 24 - Natural Frequency and Sound

20020601EnglishActivity: SetupActivity: Setup2-9-1쐽 EquipmentBattery (D.C. Power Supply) Resistor Capacitor Coil SwitchVoltage Measurement Setup (EA-2

Strona 25 - 55555555555

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-9-2쐽 Measuring Datau Prepare the Voltage Meas

Strona 26 - Column of Air Resonance and

20020601English쐽 EquipmentAC Power Supply (Switched) Resistor Capacitor CoilVoltage Measurement Setup (EA-200, graphic scientific calculator, data com

Strona 27 - 5555555555

20020601English쐽 Calculator Operationu Perform the following operation to prepare for voltage measurement using the voltageprobe.Using E-CONUsing a C

Strona 28 - = 2 f

20020601EnglishActivity: SetupActivity: Setup2-11-1쐽 EquipmentStand Heater Reflux Condenser DesiccantAuto Stirrer Beaker Round Bottom Flask (2) Mixing

Strona 29

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-11-2u As shown in the illustration, force wat

Strona 30 - ( )

20020601English2-12-1Activity: SetupActivity: Setup쐽 EquipmentStand Auto Stirrer Beaker (3)Hydrochloric Acid (Solution) Sodium Hydroxide (Solid) Disti

Strona 31 - 555555555

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-12-2쐽 Reaction Path 1 Measurementu Turn on th

Strona 32 - AC Circuit

20020601EnglishActivity: SetupActivity: Setup2-13-1쐽 EquipmentStandVoltaic Battery (Zinc Plate, Copper Plate, Dilute Sulfuric Acid Solution, Cistern)F

Strona 33

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-13-2u If the variation in voltage becomes sma

Strona 34 - Dilute Solution Properties

20020601English• The EA-200 is made up of precision components. Never try to take it apart.•Avoid dropping the EA-200 and subjecting it to strong impa

Strona 35

20020601EnglishActivity: SetupActivity: Setup2-14-1쐽 EquipmentSolar Cell Panel (Operating Voltage: 5V max.) Magnetic CompassRain Cover Wood BlockVolta

Strona 36 - Exothermic Reaction

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-14-255555555555555555555555555555555555555555

Strona 37

20020601EnglishActivity: SetupActivity: Setup2-15-1쐽 Equipment500ml Clear Plastic Bottles (3) Dry Earth (or Sand) Seawater (or Water)Styrofoam Boards

Strona 38 - 20020601

20020601EnglishActivity: Operating the EquipmentActivity: Operating the EquipmentMeasurementMeasurement2-15-2쐽 Measuring Datau Prepare the Temperature

Strona 39 - 55555555

20020601English2-16-1Program LibraryYou can download the programs used in the activities at the CASIO Website: http://world.casio.com/edu_e/

Strona 40 - Sunlight and Solar Cells

20020601English2-16-2Polarization of LightNatural Ferquency and SoundColumn of Air Resonance andthe Velocity of Sound Construction of the Musical Scal

Strona 41 - 5555555555555

20020601English2-16-3Direct Current and TransientPhenomenaAC CircuitDilute Solution PropertiesExothermic Reaction

Strona 42 - 쐽 Setting Up

20020601English2-16-4Electromotive Force of a Battery Sunlight and Solar CellsTopographic Conditions and Climate*Run the following program aftersampli

Strona 43

20020601English Channel Operation Post-Processing FFT Samples0 Clear all channels ––– ––– –––*1 Channel 1 0 Clear the s

Strona 44 - Program Library

20020601EnglishCommand 3 - Sample and Trigger SetupSample Interval Number of Samples Record Time0.00002 Number of seconds 1 to Number of samples 0 Off

Strona 45

20020601EnglishUser’s GuideEA-200http://world.casio.com/edu_e/E UnpackingEA-200 Soft case Data communication cable (SB-62)Temperature probe Optical pr

Strona 46

20020601EnglishCommand 4 – Conversion Equation Setup{ 4, Equation Number, Equation Type, Number Format, Constants }Equation Number Equation Type

Strona 47

20020601EnglishCommand APO Time(sec) 0 or 2 Abort Sampling ( *0) 3Turns sound off ––– 4Turns sound on

Strona 48 - Appendix A Command Tables

20020601Englishα-2-1Appendix B SpecificationsModel: ... CASIO EA-200Power Supply: ... Four AA-size alkali

Strona 49

20020601EnglishMEMO

Strona 51 - Command 8 - Sampling Start

SA0208-000102B Printed in JapanA342984-008V01Printed on recycled paper.CASIO COMPUTER CO., LTD.6-2, Hon-machi 1-chomeShibuya-ku, Tokyo 151-8543, Jap

Strona 52 - Appendix B Specifications

20020601EnglishAuto Power Off (APO)To extend battery life, power automatically turns off if you do not perform any operation forabout 30 minutes. APO

Strona 53

20020601EnglishChapter 1General GuideP button (rear side)*2Key Functions and Indicator Lamps Key FunctionsTo do this: Press this key:Start a sampling

Strona 54

20020601English1-2Supported Calculator ModelsConnection to a supported scientific calculator is essential if you want to get the most out ofyour EA-20

Strona 55 - A342984-008V01

20020601English1-3Using CommandsBasically, the EA-200 is controlled by commands from the connected calculator. This sectionexplains how to send comman

Komentarze do niniejszej Instrukcji

Brak uwag