Casio DT-X7 Series Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Tablety Casio DT-X7 Series. Casio DT-X7 Series User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 92
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
casio 数据采集器免费服务热线400-1166-021
CASIO
DT-X7
Series
Quick
Start
Guide
(Version
1.13)
CASIO
Computer
Ltd.
Copyright
©
2008.
All
rights
reserved.
Przeglądanie stron 0
1 2 3 4 5 6 ... 91 92

Podsumowanie treści

Strona 1 - Computer

casio 数据采集器免费服务热线:400-1166-021CASIODT-X7SeriesQuickStartGuide(Version1.13)CASIOComputerCo.,Ltd.Copyright©2008.Allrightsreserved.

Strona 2

ExternalviewsoftheDT-X7andthededicatedoptionsOptionDT-X7M10EDT-X7M10RDT-X7M10E-CNDT-X7M10R-CNFigure2.19

Strona 3 - Contents

2.3SoftwareRequiredThefollowingsoftwaretoolsandlibrariesarerequiredinordertodevelopsoftwarefortheDT-X7.Please ensure that you download or purchase the

Strona 4

Microsoft Visual Studio 2005 (not free of charge)Microsoft Visual Studio .NET 2003 (not free of charge)Windows CE Utilities for Visual Studio .NET 200

Strona 5 - Important Note

CASIODT-X7SDKDownload the DT-X7 SDK fromhttp://www2.casio.co.jp/system_en/pa/PADealer/(The site requires your user name and password. Enter your user

Strona 6 - Editorial

3.SettingUptheDevelopmentEnvironment3.1ApplicationDevelopmentThischapterexplainsaboutwhatyouneedtosetupforthedevelopmentenvironmentbeforestarting your

Strona 7 - Overview

with thedevelopment platform can be started. After application is developed, transfer it to the DeviceEmulator or an actual terminal of the DT-X7 via

Strona 8

CASIO SDK File Description Default folder pathDT-X7_SDK.msiDT-X7ExportSDKC:\ProgramFiles\WindowsCETools\wce500\DT-X7en_DevEmu500.msiDT-X7EmulatorC:\Pr

Strona 9

3.3InstallingCABFiles1.2.3.4.5.

Strona 10 - DT-X7M10R-CN

CAB file DescriptionUSBClientDTX7.110.CABUSBclientsupportedbyWindowsMobileDeviceCenterLibrary CAB fileCommonDeviceControllibrary(seenote)en_MoDev.ARMV

Strona 11 - Required

3.4eMbeddedVisualC++4.0ExportSDKforDT-X7isrequiredtodevelopapplicationsoftwarewitheMbeddedVisualC++4.0(see note 1). Follow the steps below to install

Strona 12

April2008

Strona 13

3.5VisualStudio2005Installeach‘msi’packageasdescribedinTable3.1.ThiswillinstallallthenecessarySDKandlibrary files on your PC. See Chapter 8. for basic

Strona 14

3.6VisualStudio.NET2003Installeach‘msi’packageasdescribedinTable3.1.ThiswillinstallallthenecessarySDKandlibrary files on your PC. See Chapter 8. for b

Strona 15

4.ConnectingPowerSupplytoHA-F60IO,HA-F62IO4.1HA-F60IOUsethededicatedACadaptor(AD-S42120BE)forsupplyingpowertotheHA-F60IOUSBCradle.Ensure that you conn

Strona 16 - Installing

4.ConnectaUSBcable(DT-380USB)totheUSBclientportonthebackofthecradle,andthenconnect the other end of the cable to the PC. USB host port is used when co

Strona 17

lights green. Charging the battery pack orcommunication will not proceed if it is not mounted properly.19

Strona 18

4.2HA-F62IOUsethededicatedACadaptor(AD-S42120BE)forsupplyingpowertotheHA-F62IOEthernetCradle. Ensure that you connect the AC adaptor to the cradle bef

Strona 19

4.Beforeusingthecradleports,removethecapsfromtheports.WhenusingaLAN,connectoneend of the LAN cable to the LAN port and the other end to the PC or hub.

Strona 20

lights green. Charging battery pack or communicationwill not proceed if it is not mounted properly.The LAN and USB connections cannot be used concurre

Strona 21

5.ConnectingtheDT-X7toPCTomakeconnectionestablishmentwithPC,useoneofthemethods,dependingontheOSyourPCruns, described below.

Strona 23

TableoftheContentsEditorial RecordPrefaceChapter 1.Chapter 2.2.12.22.3Chapter 3.3.13.23.33.43.53.6Chapter 4.4.14.2Chapter 5.5.15.25.2.15.2.25.35.45.55

Strona 24

5.1ActiveSyncConnectionInnearlyallcasesduringdevelopmentworkyouwillbecommunicatingwiththeDT-X7viaanActiveSync connection. There are many ways to conne

Strona 25 - HA-F62IO

5.2.1InstallingActiveSyncfortheFirstTime1.InstallActiveSyncfirst.RuntheActiveSync‘msi’file.Figure5.12.ClickInstallbutton.Figure5.224

Strona 26

3.PausetheinstallationwhenthemenuinFigure5.3isdisplayed;youhavetoinstallthedriveratthis point.Figure5.34.ConnecttheUSBcabletothePCandtheotherendtotheU

Strona 27

8.Then,chooseInstallfromalistorspecificlocation[Advanced]radiobuttoninthemenu.Figure5.59.ClickNext>button.Figure5.626

Strona 28

10.ChooseWindowsCEUSBDevicesicon.Figure5.711.ClickHaveDisk…button.Figure5.812.ClickBrowse…button.Select“wceusbsh.inf”fromthefolderyoucreatedinstep6.Fi

Strona 29

13.Theinstallationofthedriverwillstart.Figure5.1014.ClickContinueAnywaybutton.Figure5.1115.Amenumightbedisplayedtopromptyoutoinstall“wceusbsh.sys”.Thi

Strona 30

16.Nowtheinstallationofthedriverisfinished.Figure5.1217.NowgobacktotheActiveSyncInstallationWizardthatyouleftonthedesktop.ClickNext>button.Figure5.

Strona 31

18.Nowtheconnectionisestablished.Youcanselecteitherpartnershipoptionaccordingtoyourneeds. Then click Next > button.Figure5.1419.Nowtheconnectionisc

Strona 32

cause disconnection of communication.30

Strona 33

5.2.2IfActiveSyncIsAlreadyInstalledThisistheprocedureifActiveSyncisalreadyinstalledonthePC.YoujustneedtoletthePCrecognize the DT-X7 and install the cr

Strona 34

Nopartofthisdocumentmaybeproducedortransmittedinanyformorbyanymeans,electronicor mechanical, for any purpose, without the express written permission o

Strona 35

3.OntheDT-X7,inControlPanel,selectthePCConnectionoption.ConfirmthatPCConnection is set to “USB Default”. If not, select ‘USB Default’ and tap OK butto

Strona 36

5.3USBConnectionviaWindowsMobileDeviceCenterToestablishconnectionviaUSBinterfacewithPCrunsinWindowsVista,useWindowsMobileDevice Center (“WMDC”). The D

Strona 37

Figure5.2233

Strona 38

6.7.TheDT-X7startsupagain.Mount the DT-X7 on the cradle, and then follow a message appeared in the WMDC on the PC.Notes:To resume the factory defaul

Strona 39

5.4ActiveSyncConnectionviaIrDAIfthePChasanIrDAinterface,itispossibletoconnecttheDT-X7tothePCviaIrDAusingActiveSync.Followthestepsbelow:1. Choose PC Co

Strona 40

5.5ActiveSyncConnectionviaEthernetCradleThischapterdescribeshowtoestablishahighspeedLANconnectionontheWLANnon-integratedmodels (DT-X7M10E and DT-X7M10

Strona 41

7.ThefollowingTCP/IPscreenappears.SetalltheparametersinIPAddressandNameServers tabs as required and click OK button.Figure5.258.Iftheconnectionisestab

Strona 42

5.6AccessingSharedNetworkDriveonYourLANAssumingyouhaveavalidnetworkconnectionestablished,youcanaccessshareddrivesonyourPC from the File Explorer on th

Strona 44 - Connection

5.7DirectTCP/IPConnectionfromVisualStudioIfyouhaveanetworkconnectiontotheDT-X7(forexample,viaWLANortheEthernetcradle)then you can establish a direct l

Strona 45

PrefaceThisguideclearlyandconciselysetsouttheinformationdevelopersneedtoknowtogetstartedwiththe CASIO DT-X7 series development. The best methods of co

Strona 46

6.SelectDT-X7DeviceinthelistofDevices:andclickConnectbutton.ThescreeninFigure5.27 if appear indicates the success of connection establishment.Figure5.

Strona 47

Parameter Nothing is set (DHCP) ”Configure IP” is setEnable DHCP orConfigure IP”Enable DHCP” is assumed. ”Configure IP” is set.IPDoesnotdetermineIPadd

Strona 48

Parameter DescriptionSSIDEntertheSSIDofthenetworkyouwanttoconnectto.SecurityDisabNone.WEP Open in Authentication field.WPA PSK in Authentication field

Strona 49

Field / RadioButtonsDescription DefaultAdapter powerOnEnablepowertotheintegratedWLANmodule.YesOffDisablepowertotheintegratedWLANmodule.Power saveEnabl

Strona 50

Field / Radio Buttons Description DefaultWLAN configure/Status displaytoolWLANConfig/NetSearch- Use only CASIO provided WLAN tool.- Configure WLAN set

Strona 51

5.IfOKbuttoninthepopupwarningmessage(seeTable6.7fordescriptionofNetUI/NetUIradiobutton) is clicked, the screen in Figure 6.5 appears. Click OK button

Strona 52

7.eMbeddedVisualC++7.1BuildingaSimpleeVC++4.0TestProgram1.OnthePC,initiateeVC++4.0.2. Navigate to File → New in the File menu.Figure7.13.4.5.6.7.then

Strona 54

11.TheprogramwillbebuiltandautomaticallydownloadedtotheDT-X7.Bydefault,theprogramwill be copied to the root folder on the terminal. Run the program to

Strona 55

Library Dynamic Link Import Library Header FileSystemLibrarySystemLib.dllSystemLib.libSystemLib.hScannerLibraryOBReadLib.dllOBReadLib.libOBReadLib.hBl

Strona 56

ManualVersioDate edited PageContent1.01SeptemberallTentativeversion1.10OctoberallOriginalversion1.11 November200716Figures3.1and3.2inChapter3.4arecorr

Strona 57

9.Movetotheline//TODO:Placecodehereandaddthefollowingcode.intresult=SysGet180Rotate();if( result == FALSE ){SysSet180Rotate( TRUE );}else{SysSet180Rot

Strona 58

7.3SampleProgramThefollowingsampleprogramsareincludedintheDT-X7ExportSDK.Table7.2Notes:

Strona 59

Name DescriptionBluetoothLibSampleConnectstoaBluetoothprinterandprintsoutdata.CameraLibSampleTakespicturesanddisplaysthemonthescreen.IMGLibSampleScanb

Strona 60

8.VisualStudio.NET2003andVisualStudio2005

Strona 61

modifications, the solution/project from VisualStudio .NET 2003 is automatically upgraded by Visual Studio 2005. This may result in differentconfigura

Strona 62

Library Dynamic Link LibrarySystemLibrarySystemLibNet.dllScannerLibraryOBReadLibNet.dllBluetoothLibraryBluetoothLibNet.dllCameraLibraryCameraLibNet.dl

Strona 63

6.Intheeventfunctionforthebuttonclick,addthefollowingcode.If(SystemLibNet.Api.SysGet180Rotate()=0)ThenSystemLibNet.Api.SysSet180Rotate(True)ElseSystem

Strona 64

Library Dynamic Link LibrarySystemLibrarySystemLibNet.dllScannerLibraryOBReadLibNet.dllBluetoothLibraryBluetoothLibNet.dllCameraLibraryCameraLibNet.dl

Strona 65

5.Addabuttontoyourform,doubleclickitandaddthefollowingcode:if(SystemLibNet.Api.SysGet180Rotate()==0)SystemLibNet.Api.SysSet180Rotate(true);elseSystemL

Strona 66

8.3UsingCASIOLibrariesfromC++Theintentionofthischapterisjusttocheckthatthedevelopmentenvironmentissetupcorrectly.See Chapter 3.5 for information on ho

Strona 67

1.ProductOverviewTheDT-X7hasbeendesignedusingthenewconceptoftheHuman-centeredDesignProcessesandis capable of performing a wide variety of powerful fun

Strona 68

3.ChooseDT-X7intheInstalledSDKsfieldandclick>button.Figure8.44.Figure8.55.ChooseConsoleApplicationfortheApplicationtypeintheApplicationSettingsmenu

Strona 69

7.AppendthesourcecodebelowinthemainfunctionofDeviceApp.cpp.int result;result = SysGet180Rotate();if(result==FALSE){result = SysSet180Rotate( TRUE );}e

Strona 70

8.4SampleProgramThefollowingsampleprogramsareincludedintheDT-X7ExportSDK.Table8.3Notes:

Strona 71

Program DescriptionBluetoothLibSamplConnectstoaBluetoothprinterandprintsoutdata.CameraLibSampleTakespicturesanddisplaysthemonthescreen.IMGLibSampleSca

Strona 72

9.DeviceEmulatorTheDeviceEmulatorprovidesapplicationdeveloperswithanenvironmentthat,withouthavingthe actual device available, allows them to debug bas

Strona 74

Notes:1. The Device Emulator is not necessarily installed if your PC has already a Device Emulatorinstalled for other CASIO handheld terminal.2. The s

Strona 75

9.2StartinguptheDeviceEmulatorAfterinstallingallrequiredsoftwaredescribedinChapter9.1,followthestepsbelowtostartuptheDevice Emulator on your PC.1.2.Fi

Strona 77

9.3DebuggingApplicationsThischapterdescribeshowtodebugyourapplicationusingtheDeviceEmulator.Beforestartingto “Build”, establish a connection between t

Strona 78

Model no.LaserScannerLinearImagerBluetoothBluetoothWLAN(IEEE802.11b/g)DT-X7M10UNoYesYesNoNoDT-X7M10EYesNoNoYesNoDT-X7M10RYesNoNoYesYesDT-X7M10E-YesNoN

Strona 80

WhenusingVisualStudio20051.2.

Strona 82

WhenusingeMbeddedVisualC++4.01. Establish a connection between the Device Emulator and PC via ActiveSync before startingdebugging in eMbedded Visual C

Strona 83

9.4UsingtheDeviceEmulator9.4.1DT-X7DeviceEmulatorTheDT-X7DeviceEmulatoremulatesvariousoperationscarriedoutbytheactualDT-X7deviceon the PC’s screen suc

Strona 84

IndicationDescriptionLED(seeFigure9.10)TheLEDlightsgreenwhenreadingabarcodesuccessfully.VibratorON/OFFTheemulatedDT-X7vibrates.Lowbatterywarning(seeFi

Strona 85 - Indications

9.4.2I/OSimulatorTheI/OSimulatorsimulatesregistrationofbarcodes,generationoflowbatterywarning,detectionof terminal being mounted on cradle.Registratio

Strona 86 - Simulator

3.4.RegistrationofbarcodeandnoteEnter bar code data in the Barcode field (see Figure 9.14) and a note about the bar code in theNote field if necessary

Strona 87

5.6.EditingregisteredbarcodecontentHighlight a bar code in the list of registered bar codes (see Figure 9.15) and click Edit button.Figure 9.16 appear

Strona 88

DetectionofTerminalinCradle/LowBatteryWarningIf you check the I/O Box and Low Battery boxes in STATE SETTING (see Figure 9.18), thesimulator simulates

Strona 89

-DT-380USB(USBcable)- HA-F95HB (Hand Belt)Note:“-CN” attached at the end of model number denotes that the model is dedicated for the finaldestination

Strona 90 - Connecting

9.4.3ConnectingviaActiveSyncIfdebuggingwiththeDeviceEmulatoriscarriedoutineithereMbeddedVisualC++4.0orVisual Studio 2005, or transmission/reception of

Strona 91

ConnectionviaActiveSyncThe ways to establish connection of the Device Emulator via ActiveSync are ;1.StartuptheDeviceEmulatorbyreferringtoChapter9.2

Strona 92 - Resources

10.ResourcesMicrosoft’sownhttp://msdn.microsoft.com/mobility/isanextremelycomprehensiveresourceforprogrammers targeting WindowsCE .NET based devices.

Komentarze do niniejszej Instrukcji

Brak uwag