Table 5.29 Vibrator control option parameters (IT-600 and DT-X7)
0Disable
VIBRATOR Set vibration.
1Enable
Table 5.30 Scanning key option parameters
1 L Trigger key
2R Trigger key
4 Multi key
8 L Cursor key
16 R Cursor key
32 Up Cursor key
64 Down Cursor key
128 Trigger Grip key (IT-600)
KEY Specify scanning trigger keys.
For specifying multiple keys,
specify a sum of the values in
logical OR for specified keys.
256 Center Trigger key
Table 5.31 Laser beam swing angle option parameters (IT-600, DT-X7, DT-X30, IT-800, IT-300,
DT-X8) (Note 7)
0 No control
1 Wide
2 Medium
3 Narrow
SWING Specify laser beam swing angle.
(Note 8)
Table 5.32 Laser focus option parameters (IT-600, DT-X7, DT-X30, IT-800) (Note 7)
0Disable
FOCUS Set laser focus.
1Enable
Table 5.33 Notification option parameters
1 Window message notification
NOTIFICATION Specify notification mode for
scanning completion.
2 Event notification
Table 5.34 Decode level option parameters (DT-X11, IT-600, DT-X7, DT-X30, IT-800, IT-300,
DT-X8)
0 Standard (normal)
LEVEL Set decode level.
1 High